CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Cables and Connections

Revision 19

4–21

4.4.3 Control and Data Connections – CRS-300 to Modem

Table 4-1 shows the TMI and applicable data and control cables that you will need for each of

the various data types.

Table 4-1. CDM-625/A Cable Usage (RMI/TMI)

CDM-625/A Cable Usage

(see Appendix B. CABLE DRAWINGS for cable details)

Driving Traffic Data Type

CRS-310 RMI / Cable(s)

TMI / Cable(s)

G.703

(Sect. 4.4.3.2)

Bal/Unbal

Control: CA/WR0066

Data: CA-0000072

CRS-330/340

Control: CA/WR0066

Data: CA-0000072

Balanced

Control: CA/WR0066

Data: CA-0000072

CRS-325

Control: CA/WR0066

Data: CA-0000072

Unbalanced

Control: CA/WR0066

Data: PL/0813-8 (2X)

Control: CA-0000069

Data: PL/0813-8 (2X)

G.703 – Quad E1

(Sect. 4.4.3.3)

Control: CA/WR0066

Data: CA-0000073

CRS-365D

Control: CA-0000069

Data: CA-0000136 (2X)

ASI (Sect. 4.4.3.4)

Control: CA/WR0066

Data: PL/0813-8 (2X)

CRS-325

Control: CA-0000069

Data: PL/0813-8 (2X)

EIA-422 (Sect. 4.4.3.5)

Control/Data: CA/WR0066

CRS-316

Control: CA-0000069

Data: CA/WR0066

CRS-340

Control: CA/WR0066

Data:

HSSI (Sect. 4.4.3.6)

Control/Data: CA/WR0066

CRS-336

Control: CA-0000069

Data: CA/WR9189-6 with CIC-60

Adapter Module

LVDS (Sect. 4.4.3.7)

Control/Data: CA/WR0066

CRS-340

Control/Data: CA/WR0066

Ethernet

(Sect. 4.4.3.8)

Wired-thru

(No Sub-Mux)

(Sect. 4.4.3.8.1)

Control: CA/WR0066

Data: CA-0000121

CRS-316 or

CRS-336

Control: CA-0000069

Data: PP/CAT5FF7FTGY

Wired-around

(Sub-Mux)

(Sect. 4.4.3.8.2)

Control: CA/WR0066

Data (by User): CAT5 to

10/100/1000 Switch

N/A

N/A

4.4.3.1 Control Cabling Requirement (Regardless of Driving Traffic Data

Type)

For RMI connections: The Control/Data Cable CA/WR0066 (DB-25F to DB-25M, 6’) provides the

serial communication path between the Redundant CDM-625/A and the Switch (via the CRS-310

RMI) for all driving traffic data types. You must always use this cable.

For all driving traffic data types, see Figure 4-9 through Figure 4-11 and do these steps to

connect and secure the CA/WR0066 cable between the Redundant CDM-625/A and the Switch

CRS-310 RMI:

DB-25F connector labeled “Data Interface” on Redundant CDM-625/A, to

DB-25M connector labeled “P1” on the Switch CRS-310 RMI.

For TMI connections: Depending on the driving data traffic type, in addition to its use as a

control cable between the Redundant CDM-625/A and the CRS-310 RMI, you may use the