CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Front Panel Operation

Revision 19

6–10

If the CDM-Qx/QxL configuration includes Carrier-in-Carrier, this HOLDOFF

time should be no less than 8 seconds.

When the Switch is currently backing up a Traffic Modem and that offline modem’s fault clears,

the Switch continues to back it up until another active modem becomes faulted. In this case, the

RESTORE HOLDOFF is the length of time that the originally faulted modem must stay unfaulted

before the Switch automatically puts it back online so that the Redundant Modem becomes

available to bridge the newly faulted modem.

6.2.2.3.3 CONFIG: OPTIONS ALARM-MASK

ALARM MASK: MODEM-ALARMS
SW-ALARMS AUDIO (ENTER)

Select MODEM-ALARMS, SW-ALARMS, or AUDIO, and then press [ENT]. The Switch logs and

reacts to both its own faults and modem faults. Either type of faults may be masked using this

submenu. In addition, an audible buzzer can be enabled as an additional indicator.

CONFIG: OPTIONS ALARM-MASK MODEM-ALARMS

MODEM ALARM MASK: NONE
TX RX TX+RX (ENTER)

Use the

◄ ► arrow keys to select from the choices shown, and then press [ENT].

You may mask Transmit or Receive Traffic faults (or both) from being reacted to by the

Switch. This not only prevents the Switch from performing AUTO mode functions when

these modem faults are sensed, but also keeps the faults from being logged by the Switch.

These selections are global to all the modems. If masking of individual modem

faults is desired, it should be done directly on the modem. Unmasked modem

faults are logged on active modems only.

CONFIG: OPTIONS ALARM-MASK SW-ALARMS

SWITCH ALARM MASK: NONE

PSU-A PSU-B (ENTER)

Use the

◄ ► arrow keys to select NONE, PSU-A, or PSU-B, and then press [ENT].

You may select which of the plug-in power supply units to mask. Only one of the units can

be masked at a time, if needed. This would normally be done if you choose to run with only

one supply, or if you remove a faulty supply for service or replacement.