Comtech EF Data CRS-300 User Manual

Page 231

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Serial-based Remote Product Management

Revision 19

7–15

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and

qualifier)

Response to query

(Target-to-Controller)

Serial Number

N/A

9 bytes, numerical Query only.

Unit returns its 9-digit serial number.
Example: SNO=176512523

N/A

SNO?

SNO=xxxxxxxxx

(see Description of

Arguments)

Software

Revision

N/A

4 bytes, numerical Query only.

Unit returns the value of internal software revision installed

in the unit, in the form x.xx
Example: SWR=1.03 (Ver 1.03)

N/A

SWR?

SWR=x.xx

(see Description of

Arguments)

Time

TIM=

6 bytes, numerical Command or Query.

The time from midnight, in the form hhmmss, where

hh = hours, between 00 and 23,

mm = minutes, between 00 and 59, and

ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and

59 seconds from midnight.

TIM= (message OK)

TIM? (received OK, but

invalid arguments)

TIM# (message OK, but

only permitted in Remote

mode)

TIM?

TIM=hhmmss

(see Description of

Arguments)

Advertising