2 crs-300 user data connectors, 1 crs-230 controller connectors, 1 if switch control connector, db-25m – Comtech EF Data CRS-300 User Manual

Page 58: 2 485 pass-through connector, db-9f

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Switch Connectors and Pinouts

Revision 19

3–4

3.2 CRS-300 User Data Connectors

Sect. 1.4.3 Plug-in Module (Card) Assemblies

This section illustrates cabling connectors on the basis of available data or traffic interface type.

3.2.1 CRS-230 Controller Connectors

CRS-230 System Controller

Feature Connector Description

Chapter

Sect

1

IF Switch Control

3.2.1.1

2

485 Pass-Through

3.2.1.2

3

Remote Control

3.2.1.3

4

System Alarms

3.2.1.4

3.2.1.1 IF Switch Control Connector, DB-25M

Use the DB-25M IF Switch Control connector on the CRS-23 0 for

direct connection to the corresponding cabling connector on the

CRS-280 or CRS-350 switches, when used. This connector supplies

power to these switches, provides the logic interface to drive the

active modem, and decides whether the system is in bridged or backup mode. The CRS-280/350

performs the same bridging and backing up functions of the Tx and Rx IF signals identically to how

the CRS-300 processes the terrestrial data signals.

3.2.1.2 485 Pass-Through Connector, DB-9F

Use the DB-9F 485 Pass-Through connector on the CRS-230 only with

CDM-Qx/QxL modems. It is provided for 2-Wire EIA-485 serial remote

monitor and control of the modems.

Table 3-1. 485 Pass-Through User Data Connector

Pin

Signal Function

Direction

5 Ground

---

9

EIA-485 Transmit Data A

Out

4 Reserved - do not connect to this pin

---

8

EIA-485 Transmit Data B

Out

3 EIA-232 Receive Data

In

7

EIA-485 Receive Data A (see note)

In

2 EIA-232 Transmit Data

Out

6

EIA-485 Receive Data B (see note)

In

1 Ground

---