5–29

Use the CRS-300 Front Panel menu to set the Restore Holdoff Period. Do these steps:

Step

Task

1

Use the [←][→] keys to select the nested CONFIG: OPTIONS HOLDOFFS menu.

2

Change the RESTORE HOLDOFF to any number in the range of 1 to 99 seconds.

5.6.2.6 Set the Alarm Masks

Another way to adjust the Switch's reaction in AUTO mode is to mask modem faults. You may

disable modem Rx, Tx or both fault types so that the Switch does not react to them. This

masking prevents the Switch from taking automatic action and prevents the logging of the faults

in the stored events list.

These masks are global to all the modems attached to the Switch.

Use the CRS-300 Front Panel menu to set the Alarm Masks. Do these steps:

Step

Procedure

1

Use the [←][→] keys to select the nested CONFIG: OPTIONS MASKS MODEM-ALARMS

menu.

2

Set the mask parameters as desired.

In the event that a second fault occurs, another way to influence Switch behavior is via Priority

Mode. For detailed information on Priority Mode, see Sect. 6.2.2.3.1 CONFIG: OPTIONS

PRIORITY

.