CRS-300 1:10 Redundancy Switch
MN/CRS300.IOM
Appendix C
Revision 19
C–13
The modem automatically sets the transceiver address:
Transceiver MCA = (Master ESA) + 4 = (Slave ESA) + 3
•
Distant Transceivers 1 & 2
(1:1 configuration):
o First, set up the modem, as described earlier in this section.
o On the modem, key to Enable ODU.
The modem automatically sets the transceiver addresses:
MCA of Transceiver #1 = (Master ESA) + 4
MCA of Transceiver #2 = (Master ESA) + 5
C.4 M&C Applications
The system is set up such that it may be communicated to by an M&C application, e.g., SatMac
or CMCS. In the SatMac application, go to the Link Edit Mode screen to enter the Monitor &
Control Addresses (MCA).