Cables and Connections

Revision 19

4–22

CA/WR0066 cable as: a control cable between the Traffic CDM-625/A(s) and the CRS-330 or

CRS-340 TMI; as a data cable with the CRS-316 TMI; and as a combination control/data cable for

use with the CRS-340 TMI.

For specific details regarding the CA/WR0066 cable’s use as a TMI control and/or data cable, see

the data connection cabling instructions that follow for each driving traffic data type.

Additionally, when you use the CRS-316, CRS-325, or CRS-336 TMI, you must use the

CA-0000069 (HD-15M to DB-9M, 6’) Control Cable between the installed TMI(s) and Traffic

CDM-625/A(s).

See Table 4-1 in Sect. 4.4.3, and read the data connection cabling instructions that follow, for

use of this cable with the pertinent driving traffic data type.

4.4.3.2 G.703 Balanced / Unbalanced Data Connections

If G.703 (Balanced/Unbalanced) is the driving traffic data type, your means of interconnection

depends on which Switch TMI is in use. Figure 4-9 depicts use of the CRS-330 and CRS-340 TMIs

for G.703, while Figure 4-10 depicts use of the CRS-325 TMI for G.703.

G.703 traffic TMIs are not compatible with the CRS-365D Quad E1 traffic TMI when

you use both TMIs within the same Switch.

Make all connections according to the information that follows:

► If you use the CRS-330 or CRS-340 TMIs (as shown in Figure 4-9), do these steps:

First, connect the Control/Data Cable CA/WR0066 (for control purposes) between the

Redundant CDM-625/A and the Switch RMI (see Sect. 4.4.3.1).

Next, do these steps to connect and secure the Control/Data Cable CA/WR0066 (for control

purposes) between the Switch TMI(s) and Traffic CDM-625/A(s):

DB-25M connector labeled “P1” on the Switch TMI(s), to

DB-25F connector labeled “Data Interface” on the Traffic CDM-625/A(s).

Finally, do these steps to connect and secure the Data Cable CA-0000072 (DB-15F to DB-9M,

6’). Use these cables for Balanced or Unbalanced G.703 data between the Switch RMI or

TMI(s) and the Redundant and Traffic CDM-625/A(s):

DB-15M connector labeled “P2” on the Switch RMI or TMI(s), to

DB-9F connector labeled “Balanced G.703” on the Redundant and Traffic CDM-625/A(s).

► If you use the CRS-325 TMI (as shown in Figure 4-10), do these steps:

Specific cabling requirements apply for operation with the CDM-625/A.