Appendix C. ADDRESSING

SCHEME INFORMATION

C.1 Addressing Overview

A CRS-300 1:10 Redundancy Switch provides 1:10 redundancy; that is, you may use the CRS-300 to

control one Redundant Modem and up to 10 Traffic Modems.

You can remotely communicate to the Switch or any of the modems, via the DB-9, EIA-232 or

EIA-485 remote connector on the CRS-230 Switch Controller card (installed in the CRS-300). A

direct User-to-modem connection is not permissible in this configuration – master operation is

restricted to the Switch in a redundancy system.

For Switch-to-modem communications with the CDM-625/A, CDM-570/A, CDM-570L/AL,

SLM-5650/5650A, CDM-710, CDM-700, and CDM-600/L modems, the Switch uses serial

communications via a DB-25 data cable or an HD-15 Control Cable that is connected between

each modem and the Switch-installed TMIs.

For Switch-to-modem communications with the CDM-Qx/QxL modems, the Switch uses EIA-485

communications via a DB-9 multi-drop cable that is connected from the “485 Pass-Through”

connector on the CRS-230, and then daisy-chained to each of the modems.

For modems that are configured for EDMAC framing, Monitor & Control (M&C) information may

be communicated to the modems and transceivers at the distant-end of the link. In order for an

M&C application to be able to communicate with the various devices connected to the Switch,

the correct addresses must be used.

This appendix provides details of the address requirements to allow M&C of the Switch, various

modems, and transceivers that may be included in a CRS-300 1:N Redundancy System.