CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Front Panel Operation

Revision 19

6–11

CONFIG: OPTIONS ALARM-MASK AUDIO

AUDIO MASK: NONE SW-ALMS
MODEM-ALMS BOTH (ENTER)

Use the

◄ ► arrow to select from the choices shown, and then press [ENT].

For all unmasked Switch or modem alarms, you may select which alarm types should force

the Switch to react with an audible buzzer located behind the front panel. In addition, a

relay closure to ground activates on Pin 20 of the System Alarms connector so that you may

attach other indicators.

6.2.2.4 CONFIG: REMOTE

SELECT REMOTE CONTROL:
LOCAL REMOTE (PRESS ENT)

Use the

◄ ► arrow keys to select LOCAL or REMOTE, and then press [ENT].

6.2.2.4.1 CONFIG: REMOTE LOCAL

When you select LOCAL, the Switch disables remote control, although remote monitoring is

always possible.

6.2.2.4.2 CONFIG: REMOTE REMOTE

REMOTE CONTROL: BUADRATE
INTERFACE (PRESS ENTER)

Use the

◄ ► arrow keys to select BAUDRATE or INTERFACE, and then press [ENT].

CONFIG: REMOTE REMOTE BAUDRATE

REMOTE CONTROL: BUADRATE
INTERFACE (PRESS ENTER)

You may select the baud rate of the remote control bus, connected locally to the M&C

computer. Use the

◄ ► arrow keys to change the baud rate. Values of 300, 1200, 2400,

4800, 9600 and 19200 baud are possible. Press [ENT] when done.

This setting does not affect the internal communications between the

Switch and the modems.