8 cdm-710g/710gl modem connections, 1 rmi/tmi limitations and considerations, 2 interface combinations – Comtech EF Data CRS-300 User Manual

Page 136

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Cables and Connections

Revision 19

4–62

4.8 CDM-710G/710GL Modem Connections

If adding a modem to an operating 1:N system, care needs to be taken not to interfere with the

existing traffic. The cabling, power-up sequence and communication connections must be

correct to avoid contention in the system from the modem Tx carrier. This information is

detailed in Sect. 6.2.2.5 CONFIG: ACTIVE (Activate Modems).

4.8.1 RMI/TMI Limitations and Considerations

1)

Traffic modems with differing data types are not supported by the Redundant

Modem. For example, the Switch can not be populated with Traffic modems

with ASI and Traffic modes with HSSI.

2)

Depending on the traffic data type, the appropriate jumper settings are

provided on the Switch TMI to ensure proper operation for HSSI with CA/TA

signals using the CRS-336 TMI. See Chapter 5. MODEM, TMI,

AND

SWITCH

CONFIGURATION for this important configuration information.

4.8.2 Interface Combinations

The two plug-in interface module slots in the CDM-710G/710GL allow for many possible

interface card combinations. Table 4-2 details the interface card combinations that are

compatible with the Switch.

Table 4-2. CDM-710G/710GL Interface Card Combinations

CDM-710G/710GL Unit Configuration

1:N CRS-300 Configuration

Notes

Interface Slot 1

Interface Slot 2

TMI Card

RMI Card

G.703 (CDI-10-1)

None

CRS-325

CRS-306

-

G.703 (CDI-10-1)

GigE (CDI-70)

Can be used as

Redundant Unit

HSSI (CDI-60)

None

CRS-336

-

None

GigE (CDI-70)

CRS-306

-

HSSI (CDI-60)

GigE (CDI-70)

Can be used as

Redundant Unit

Notes:

1)

The Redundant Modem must have the same interface cards in each slot as any of the Traffic

Modems.

2)

The Traffic Modem must have either the same cards in each slot as any of the other Traffic

Modems have, or a blank panel installed.