2 verify each active modem connection – Comtech EF Data CRS-300 User Manual

Page 190

Advertising
background image

CRS-300 1:10 Redundancy Switch

MN/CRS300.IOM

Modem, RMI/TMI, and Switch Configuration

Revision 19

5–26

Once you press [ENT], the Switch Status LED turns RED until the Switch polls each activated

modem and correctly programs the bridged modem configuration into the Redundant Modem.

The Redundant Modem may take several seconds to configure. Once this programming

completes successfully, the RED LED turns GREEN. If the LED remains RED, you must investigate

the problem – use the CRS-300 Front Panel menu to check the communication status:

MONITOR: COMM-STATE or MONITOR: SW-ALARMS

Another option is to view the I/O. Review the nested MONITOR: I/O screen. Communication is

slowed to aid viewing. This screen shows the actual messages to and from the modems; if there

are no responses from a modem, check the addressing scheme carefully and verify that your

modem communication setups are correct.

To deactivate a modem, see Sect. 6.2.2.5 CONFIG: ACTIVE (Activate Modems).

5.6.2.2 Verify Each Active Modem Connection

The LEDs are arranged in columns corresponding to each modem, and should accurately reflect

the status of each. Use the CRS-300 Front Panel menu to verify the modem connections. Do

these steps:

Step

Task

1

Verify that the Status LED for each modem shows a GREEN light, indicating no faults. (The Switch

Status LEDs will reflect each modem’s Status LED.)

2

Verify that the Online LED is lit for all connected TMIs with the modems attached.

3

Verify that the Online LED is not lit for the Redundant Modem.

4

Verify that the Bridge LED is lit for only one Traffic Modem.

For modems: Use the read-only INFO and MONITOR screens to view the status of the modems,

in addition to viewing the LEDs.

For the Switch: Use the read-only MONITOR: COMM-STATE screen to verify that the modems

are responding via remote control.

For real-time monitoring: Use the read-only MONITOR: I/O screen to verify that the modems

are responding via remote control. Communication is slowed to aid viewing.

Do not leave the Switch in this view.

Do not leave the Switch in this view.

Advertising