Theory of Operation

SMS-758 Modem Protection Switch

4–44

MN/SMS758 Rev. 3

1

JP2

BACKUP

INTERFACE

SWITCH

AS/1694

15

16

.

JP1

1

2

. .

.

. . . . . . .

.

. . . . . . .

.

Figure 4-17. Backup IBS Jumper Diagram

Table 4-8. Backup IBS Jumpers

Operation

Jumper

Pins

Comments

Normal

JP1

5 through 6
7 through 8
13 through 14
15 through 16

Independent RST
and CTS

Special

JP1

1 through 2
3 through 4
9 through 10
11 through 12

CTS, tied to RTS,
TXD of ESC on
CTS lines

G.703

JP2

1 through 2
3 through 4

RS-422, V.35

JP2

No connections
No connections