A.3.3.2 backup modem address, A.3.3.3 prime modem interface type, A.3.3.4 backup modem interface type – Comtech EF Data SMS-758 User Manual

Page 128

Advertising
background image

Remote Control Operation

SMS-758 Modem Protection Switch

A–6

MN/SMS758 Rev. 3

A.3.3.2 Backup Modem Address

Address “0” may be used to clear the address field of modem “x”.

Command:

<add/ADD_Bx_yyy”cr”

Response:

>add/ADD_Bx_yyy”cr””lf”]

Status Only:

<add/ADD_Bx”cr”

Response:

>add/ADD_Bx_yyy”cr””lf”]

Where:

x = 1 to 8 (backup modem number).
yyy = 1 to 255 (backup modem address).

A.3.3.3 Prime Modem Interface Type

Command:

<add/INT_x_y”cr”

Response:

>add/INT_x_y”cr””lf”]

Status Only:

<add/INT_x”cr”

Response:

>add/INT_x_y”cr””lf”]

Where:

x = 1 to 8 (prime modem number).

y = 1 (for 15 D), 2 (for V.35), 3 (for RS422), 4 (for DCTN), 5 (for IDR), or 6 (for
OTHER).

A.3.3.4 Backup Modem Interface Type

Command:

<add/INT_Bx_y”cr”

Response:

>add/INT_Bx_y”cr””lf”]

Status Only:

<add/INT_Bx”cr”

Response:

>add/INT_Bx_y”cr””lf”]

Where:

x = 1 or 2 (backup modem number).
y = 1 (for DS1), 2 (for V.35), or 3 (for RS-422).

Advertising