Remote Control Operation

SMS-758 Modem Protection Switch

A–12

MN/SMS758 Rev. 3

A.3.5.5 Load Modem Configuration(s)

These commands tell the switch to poll the specified modems for configuration
information (via the modem remote control serial communications link). Configurations
received without error are loaded into the switches memory.

A.3.5.5.1 Load All Active Modems Configurations

This command loads all the active modems configurations and gives status of the load
process (OK/FLT).

Command:

<add/LMC_ALL”cr”

Response:

>add/LMC_ALL”cr”
MOD_1_yyy”cr”
DMD_1_yyy”cr”
MOD_2_yyy”cr”
DMD_2_yyy”cr”
MOD_3_yyy”cr”
DMD_3_yyy”cr”
MOD_4_yyy”cr”
DMD_4_yyy”cr”
MOD_5_yyy”cr”
DMD_5_yyy”cr”
MOD_6_yyy”cr”
DMD_6_yyy”cr”
MOD_7_yyy”cr”
DMD_7_yyy”cr”
MOD_8_yyy”cr”
DMD_8_yyy”cr”
MOD_B1_yyy”cr”
DMD_B1_yyy”cr”
MOD_B2_yyy”cr”
DMD_B2_yyy”cr””lf”]

Where: yyy = OK or FLT.

Note: Response shown is for a system with all possible modulators and demodulators
active. Only active modulator and demodulator configurations will be loaded and load
status reported.

A.3.5.5.2 Load Prime Modem Configuration

Command:

<add/LMC_x”cr”

Response:

>add/LMC_x”cr”
MOD_x_yyy”cr”
DMD_x_yyy”cr””lf”]

Where:

x = 1 to 8 (prime modem number).
yyy = OK or FLT.