B.3.5.7.2 verify prime modem configuration, B.3.5.7.3 verify backup modem configuration, B.3.5.8.2 demodulator operational faults status – Comtech EF Data SMS-758 User Manual

Page 160

Advertising
background image

Remote Control Operation

SMS-758 Modem Protection Switch

B–16

MN/SMS758 Rev. 3

B.3.5.7.2 Verify Prime Modem Configuration

Command:

<add/VMC_x”cr”

Response:

>add/VMC_x”cr”
MOD_x_yyy”cr”
DMD_x_yyy”cr””lf”]

Where:

x = 1 to 8 (prime modem number).
yyy = OK or FLT.

B.3.5.7.3 Verify Backup Modem Configuration

Command:

<add/VMC_Bx”cr”

Response:

>add/VMC_Bx”cr”
MOD_Bx_yyy”cr”
DMD_Bx_yyy”cr””lf”]

Where:

x = 1 or 2 (backup modem number).
yyy = OK or FLT.

B.3.5.8 Operational Status Commands (Faults)

B.3.5.8.1 Modulator Operational Faults Status

Command:

<add/MOF_”cr”

Response:

>add/MOF_”cr”

BU_OP_FLT_xxxxxxxx”cr””lf”]

Backup operation faults

(see Note below)

Where: x = 1 to 8 (prime mod number).

Note: Fault status data is only returned if fault conditions exist.

B.3.5.8.2 Demodulator Operational Faults Status

Command:

<add/DOF_”cr”

Response:

>add/DOF_”cr”

BU_OP_FLT_xxxxxxxx”cr”

Backup operation faults

(see Note below)

DL_FLT_yyy”cr””lf”]

All Demods on downlink “y” faulted

(see Note below)

Where:

x = 1 to 8 (prime demod number).
y = 1, 2, 3 (faulted downlink number).

Note: Fault status data is only returned if fault conditions exist.

Advertising