Installation

MN/SMS758 Rev. 3

2–3

2.2.2 Modem Setup

J28 through J35 are the eight IF outputs available to connect to the customer-supplied
uplink power combiners.

J7 through J10, and J12 through J15, are the downlink inputs available for use with up to
eight customer-supplied downlink splitters. The following steps describe the uplink and
downlink connections:

1. Connect the IF output cables 1 through 8 to the appropriate customer-furnished

uplink signal combiner inputs.

2. Connect the downlink input cables 1 through 4, or 1 through 7, to the appropriate

customer-furnished downlink splitters.

3. When using the 7 downlink option, connect J16 (backup 2 output) to J7, and

specify 7 downlinks/1 backup in the System menu.

Note: Be sure to terminate all unused IF outputs and downlink inputs with the
supplied 75

BNC terminations.

2.3 System Requirements

The switch, with all interface assemblies installed (Figure 2-1), is capable of operating as
a 2:8 protection switch. This means that two full-duplex standby modems back up eight
full-duplex primary modems.

Note: When IDR interface AS/0895 is used, only one backup is available.

The switch can be configured in any combination including:

TX only modems.

RX only modems.

Mixed interfaces (limited to two).

Multiple uplinks (limited to eight).

Multiple downlinks (limited to four with 2 backups, 7 with 1 backup).

Multiple data rate and code rate operation.

Refer to Section 3.2 for a complete explanation of the configuration function.