Appendix A.

REMOTE CONTROL OPERATION:

MODEM SWITCH

This appendix defines the protocol and command structure for the “modem switch” style
of remote control and status monitoring of the EFData SMS-758 switch. With modem
switch software, when the switch detects either a modulator or demodulator failure on
the prime modem, both the modulator and demodulator functions will be switched to the
backup modem.

Firmware number:

FW/0713-33J

Software version:

5.10

A.1 General

Remote controls and status information are transferred via an RS-485 (optional RS-232C)
serial communications link. For RS-232C communication, switch SP1-5 on the M&C
module must be turned ON.

Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.

The remote communications link is operated in a half-duplex mode. Communications on
the remote link are initiated by a remote controller or terminal.

The switch never transmits data on the link unless it is commanded to do so.

A.2 Message Structure

The ASCII character format used requires 11 bits/character:

1 start bit

7 information bits

1 parity bit (odd/even)

2 stop bits