3 remote baud rate, 4 remote address – Comtech EF Data SMS-758 User Manual

Page 63

Advertising
background image

SMS-758 Modem Protection Switch

Theory of Operation

MN/SMS758 Rev. 3

4–3

4.1.3 Remote Baud Rate

The eight position switch pack, SP1, on the M&C module programs the external remote
serial communications baud rate and parity. Set the switches to ON (nearer the PCB) or
OFF (away from the PCB) to select parity and baud rate.

SP1 switch position 1 (SP1-1) sets the parity:

“OFF” for even parity

“ON” for odd parity

SP1 switch positions 2, 3, and 4 (SP1-2, SP1-3, and SP1-4) set the baud rate as follows:

Baud

SP1-2

SP1-3

SP1-4

110

ON

ON

ON

150

ON

ON

OFF

300

ON

OFF

ON

600

ON

OFF

OFF

1200

OFF

ON

ON

2400

OFF

ON

OFF

4800

OFF

OFF

ON

9600

OFF

OFF

OFF

4.1.4 Remote Address

The switch connects to an RS-485 remote communication link. To communicate on this
link, each unit must have a unique address between 1 and 255. (0 cannot be a device
address, as it is the global address for all devices.) To set an address, use the 8-position
switch pack, SP2, on the M&C module.

Addresses are binary coded numbers:

Switch position 1 (SP2-1) is the most significant bit.

Switch position 8 (SP2-8) is the least significant bit.

To turn ON any switch, move it to the position closer to the PCB. For example:

Address

SP2-1

SP2-2

SP2-3

SP2-4

SP2-5

SP2-6

SP2-7

SP2-8

1

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

3

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

5

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

9

OFF

OFF

OFF

OFF

ON

OFF

OFF

ON

17

OFF

OFF

OFF

ON

OFF

OFF

OFF

ON

33

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

65

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

129

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

255

ON

ON

ON

ON

ON

ON

ON

ON