MN/SMS758 Rev. 3

B–1

Appendix B.

REMOTE CONTROL OPERATION:

INDEPENDENT MOD/DEMOD

This appendix defines the protocol and command structure for remote control and status
monitoring of the EFData SMS-758 switch.

Firmware number:

FW/0713-36L

Software version:

6.1.2

B.1 General

Remote controls and status information are transferred via an RS-485 (optional RS-232C)
serial communications link. For RS-232C communication, switch SP1-5 on the M&C
module must be turned ON.

Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.

The remote communications link is operated in a half-duplex mode. Communications on
the remote link are initiated by a remote controller or terminal.

The switch never transmits data on the link unless it is commanded to do so.

B.2 Message Structure

The ASCII character format used requires 11 bits/character:

1 start bit

7 information bits

1 parity bit (odd/even)

2 stop bits

Messages on the remote link fall into the categories of commands and responses.
Commands are messages which are transmitted to a modem protection switch, while
responses are messages returned by a modem protection switch in response to a command.