A.3.4 status commands/responses, A.3.3.5 modem priority, A.3.3.6 modem online delay – Comtech EF Data SMS-758 User Manual
Page 129
SMS-758 Modem Protection Switch
Remote Control Operation
MN/SMS758 Rev. 3
A–7
A.3.3.5 Modem Priority
Command:
<add/MP_x_y”cr”
Response:
>add/MP_x_y”cr””lf”]
Status Only:
<add/MP_x”cr”
Response:
>add/MP_x_y”cr””lf”]
Where:
x = 1 to 8 (prime modem number).
y = 1, 2, or 3 (1 is high priority, 2 is medium priority, and 3 is low priority).
A.3.3.6 Modem Online Delay
Command:
<add/MD_x_yyy.y”cr”
Response:
>add/MD_x_yyy.y”cr””lf]
Status Only:
<add/MD_y”cr”
Response:
>add/MD_x_yyy.y”cr””lf]
Where:
x = 1 to 8 (prime modem number).
yyy.y = .5 to 127 (time in increments of .5 seconds), AUTO, or NONE.
A.3.4 Status Commands/Responses
A.3.4.1 Configuration Status
A.3.4.1.1 Prime Modulator Configuration Status
The Prime Modulator Configuration Status command causes a block of data to be
returned by the SMS-758. The block of data reflects the stored configuration of the
modulator selected.
Command:
<add/MCS_x”cr”
Response:
>add/MCS_x”cr”
MA_yyy”cr”
Mod Active (YES/NO)
MP_y”cr”
Modem Priority (1, 2, or 3)
MD_yyy.y”cr”
Modem Online Delay
ADD_yyy”cr”
Modem Address
INT_y”cr””lf”]
Modem Interface Type
Where: x = 1 to 8 (prime modulator number).