C.1.3 downlink inputs, C.1.4 backup demod (j11), C.2 front panel operation – Comtech EF Data SMS-758 User Manual

Page 171

Advertising
background image

SMS-758 Modem Protection Switch

7 Downlink Option

MN/SMS758 Rev. 3

C–3

C.1.3 Downlink Inputs

These are the downlink input connectors. These connections provide the inputs to the
downlink switching matrix.

Connectors J12 through J15 are the downlink inputs 1 through 4.

When the 7 downlink option is being used, connectors J8 through J10 are the downlink
inputs 5 through 7.

When the 7 downlink option is not being used, connectors J8 through J10 are downlink
inputs to backup modem 1. Downlink inputs that are not being used must be terminated in
75

.

C.1.4 Backup Demod (J11)

This is the backup demod output connector. It connects to the backup modem RX IF input.

When the 7 downlink option is being used, there is only one backup demod output.

C.2 Front Panel Operation

Refer to Chapter 3 for front panel operation information.