B.3.2.3 Prime Demodulator Transponder

Command:

<add/DT_x_y”cr”

Response:

>add/DT_x_y”cr””lf”]

Status Only:

<add/DT_x”cr”

Response:

>add/DT_x_y”cr””lf”]

Where:

x = 1 to 8 (prime demodulator number).
y = 1, 2, 3 or 4 (transponder number, four transponders option).
y = 1, 2, 3, 4, 5, 6, or 7 (transponder number, seven transponders option).

Note: See the “DTO_” command for the definition of downlink transponder option.

B.3.2.4 Prime Demodulator Online Delay

Command:

<add/DD_x_yyy.y”cr”

Response:

>add/DD_x_yyy.y”cr””lf]

Status Only:

<add/DD_y”cr”

Response:

>add/DD_x_yyy.y”cr””lf]

Where:

x = 1 to 8 (prime demodulator number).
yyy.y = .5 to 127 (time in increments of .5 seconds), AUTO, or NONE.

B.3.2.5 Backup Demodulator Active

Command:

<add/DA_Bx_yyy”cr”

Response:

>add/DA_Bx_yyy”cr””lf”]

Status Only:

<add/DA_Bx”cr”

Response:

>add/DA_Bx_yyy”cr””lf”]

Where:

x = 1 or 2 (backup demodulator number).
yyy = YES or NO.

Note: Backup number two cannot be active if the downlink transponders option is
specified to be “7”. See the “DTO_” command.