B.3.3 modem configuration commands/responses, B.3.3.2 backup modem address, B.3.3.3 prime modem interface type – Comtech EF Data SMS-758 User Manual

Page 151

Advertising
background image

SMS-758 Modem Protection Switch

Remote Control Operation

MN/SMS758 Rev. 3

B–7

B.3.3 Modem Configuration Commands/Responses

B.3.3.1 Prime Modem Address

Address “0” may be used to clear the address field of modem “x”.

Command:

<add/ADD_x_yyy”cr”

Response:

>add/ADD_x_yyy”cr””lf”]

Status Only:

<add/ADD_x”cr”

Response:

>add/ADD_x_yyy”cr””lf”]

Where:

x = 1 to 8 (prime modem number).
yyy = 1 to 255 (prime modem address).

B.3.3.2 Backup Modem Address

Address “0” may be used to clear the address field of modem “x”.

Command:

<add/ADD_Bx_yyy”cr”

Response:

>add/ADD_Bx_yyy”cr””lf”]

Status Only:

<add/ADD_Bx”cr”

Response:

>add/ADD_Bx_yyy”cr””lf”]

Where:

x = 1 to 8 (backup modem number).
yyy = 1 to 255 (backup modem address).

B.3.3.3 Prime Modem Interface Type

Command:

<add/INT_x_y”cr”

Response:

>add/INT_x_y”cr””lf”]

Status Only:

<add/INT_x”cr”

Response:

>add/INT_x_y”cr””lf”]

Where:

x = 1 to 8 (prime modem number).

y = 1 (for 15 D), 2 (for V.35), 3 (for RS-422), 4 (for DCTN), 7 (for IBS), 8 (for D&I),
5 (for IDR), 6 (for OTHER), or 9 (for IDR 2:N).