Connecting to a contact closure device – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 100

Advertising
background image

CHAPTER 9 • CLICK 512

99

Note

If you do not save your settings to your Click 512, they will be lost the next time you
power the device down.

˽

The Tools menu contains five options for working with your device. Reset > System

power cycles your device, while Reset > Factory Default restores your device to the

settings with which it was shipped. Restore will restore the driver to the settings cur-

rently saved on the Click 512, erasing any unsaved changes. Upgrade can be used to

manually upgrade to the most current firmware for your device. Hex View changes the

view of certain settings in the driver to hexadecimal.

˽

Clicking the Quit menu exits the driver and returns you to the Click Supervisor main

page.

Connecting to a Contact Closure Device

Once you have finished the computer configuration, connect the Click 512 to a contact clo-

sure device, specifically the Click 104, Click 112 or 114. Enter Device Setup mode through

the menu selection process (green solid), attach the device via the RS-485 top port, then

put the contact closure device in AC (Actuation) mode (see the appropriate chapters of the

Click 100–400 Series User Guide for information on how to enter actuation mode for the

Click 104/112/114).