Sensor emulation – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 60

Advertising
background image

CHAPTER 7 • CLICK 510

59

˽

Press – Pressing and then quickly releasing the push-button allows you to make a

selection in the menu.

The menu is used to select and run an application’s operating functions. Select an operation

function by navigating though the main menu (multicolored LEDs) and the submenus (yel-

low and red LEDs) as described below:
1 Enter the main menu by holding the push-button down. Continue holding the push-

button to cycle through the entire menu of functions.

2 Release the push-button once the cycle reaches the desired function (see Table 7.1).

3 Press the push-button again to select the function. Once selected, the function will

either start running or the first submenu (yellow LEDs) will start (the first LED will

light up).

4 Hold the push-button to cycle through the first submenu.

5 Release the push-button once the desired submenu selection is displayed.

6 Press the push-button again to select the function. Once selected, the function will

either start running or the second submenu (red LEDs) will start (the first LED will

light up).

7 Hold the push-button to cycle through the second submenu.

8 Release the push-button once the desired submenu selection is displayed.

9 Press the push-button again to select the function. The function will now start running.

Sensor Emulation

Sensor Emulation is the first mode presented in the menu selection process (blue flashing).

It is also the default mode and will be running the first time the device is powered on. (After

you have switched to another operating mode, the device will return to that mode after a

power cycle.)

Sensor Emulation mode is used for testing connections between a sensor and other devices.

The Click 510 can mimic a SmartSensor 105 and send traffic data, allowing you to see if

breaks in communication are caused by the communication channel or by the sensor itself.

It also allows you to check the functionality of an assembled traffic cabinet before attaching

a sensor. In both these cases, the response can be monitored with a contact closure module

such as the Click 100, 172 or 174.

This mode has two submenus on which you can specify the traffic data and how it will be sent.

1st LED

2nd LED

3rd LED

4th LED

Submenu 1

(Yellow LEDs)

1 second

0.25 – 1 second

Switch

-

Submenu 2

(Red LEDs)

17’/60’ 30 – 60
mph

Random Traffic

Diagnostic Traffic -

Table 7.2 – Sensor Emulation Submenus (Yellow and Red LEDs)

Advertising