CHAPTER 9 CLICK 512

Serial Convert Mode (yellow solid)

Serial Convert mode is the third menu option. This mode acts as a serial converter between all

the different communications ports, which may be useful for debugging communication links.

Note

The baud rate for serial conversion will match the baud rate set for communications
to SmartSensor HD (the default is 9600 bps).

Reset (red flashing)

The red flashing mode resets the Click 512 to factory defaults. If a device is not responding

and not communicating, resetting the device may fix the problem. Once in reset mode, use

submenu 1 (yellow LEDs) to select which level of settings should be reset:

˽

First LED solid – Reset all settings except serial number and XML variable map.

˽

Second LED solid – Reset all settings except serial number.

After being reset, the Click 512 will return to the last mode that it was in.

Computer Configuration

The Click 512 must be configured using the Click Supervisor software. See Chapters 4 and

5 of this document for instructions on how to download and install Click Supervisor and

how to connect to your device using the software.

The Click 512 can be configured using the Expert driver (see Figure 9.88).

Figure 9.8 – Selecting a Driver