Yaskawa VS-616PS5 Series Programming Manual User Manual

Page 106

Advertising
background image

106

VS-616PS5 Programming Manual

F1-04 PG deviation detection stopping method

0: Ramp to Stop

2: Fast-Stop

1: Coast to Stop

3: Alarm Only

-

0~3

3

B

F1-05 PG rotation selection

0: CCW

1: CW

-

0/1

1

Q

F1-08 Overspeed detection level

%

0~120

115

A

F1-09 Overspeed detection time

s

0~2.0

0.0

A

F1-10 PG deviation detection level

%

0~50

10

A

F1-11 PG deviation detection time

s

0~10.0

0.5

A

F1-13 PG open phase detection delay time

s

0.0~10.0

3.0

A

F2

A1-14B Setup

F2-01 Bipolar or unipolar input selection

0: 3-channel individual

1: 3-channel additional

-

0/1

0

A

F3

D1-08/DI-16H Setup

F3-01 Digital input option

0: BCD 1%

2: BCD 0.01%

1: BCD 0.1%

7: Binary

-

0~7

0

A

F4

AO-08/AO-12 Setup

F4-01 Analog output Channel 1 selection

1: Speed reference

2: Output frequency

3: Inverter output current

5: Motor speed

6: Output voltage

7: DC bus voltage

8: Output power

9: Torque reference (internal)

15: External terminal 13 input voltage

16: External terminal 14 input voltage

17: External terminal 16 input voltage

18: Motor secondary current (I

q

)

19: Motor excitation current (I

d

)

20: Primary frequency after SFS

21: Speed controller ASR input

22: Speed controller ASR output

27: q Axis current control reference

28: d Axis current control reference

29: Voltage limit control output

30: q Axis current control output

31: d Axis current control output

32: Output voltage reference (V

q

)

33: Output voltage reference (V

d

)

45: External torque reference

46: Torque compensation value

49: Control section software number

50: Speed detection PG counter value

53: PID feedback

-

1~60

5

A

F4-02 Analog output channel 1 gain

-

±300.0

1.0

A

F4-03 Analog output channel 1 bias

%

±109.2

0.0

A

F4-04 Analog output channel 2 selection

(same as F4-01)

-

1~60

3

A

F4-05 Analog output channel 2 gain

-

±300.0

1.0

A

No.

Parameter Description

Unit

Setting Range

Default

Access

Level

User

Setting

Appendix