Setting Range:

0.0 to 605.0

Factory Default:

0.00 (E1-02=1000)

Set to the motor rated current as indicated on the motor nameplate for motor capacity
7.5kW or less is set in units of 0.01A, and for motor capacity 11kW or greater, in units
of 0.1A.

Setting Range:

2, 4, 6, or 8

Factory Default:

4 (E1-02=1000)

Use this parameter to set the number of motor poles.

Setting Range:

0 to 6000rpm

Factory Default:

1 (E1-02=1000)

Set the maximum motor speed with this parameter in units of 1rpm. Avoid the con-
stant horsepower range due to lack of field weakening control in the brushless DC
machine.

Setting Range:

0 to 6000rpm

Factory Default:

1 (E1-02=1000)

Base motor speed is set in units of 1rpm.
.

Setting Range:

0 to 6000rpm

Factory Default: 30 (E1-02=1000)

The minimum motor operating speed is set in units of 1rpm.

E1-04 Motor Rated Current

Q

E1-05 Number of Motor Poles

Q

E1-06 Maximum Motor Speed

Q

E1-07 Base Motor Speed

Q

E1-08 Minimum Motor Speed

Q

Section E: Motor Parameters

E1 V/f Pattern