VS-616PS5 Programming Manual

95

O

Operator Parameters

O1

Monitor Selection

The operation menu allows simple viewing of four monitor variables (via the DSPL
key). These are Speed ref, Speed out, I

out

, and a user-selected monitor. Using the

table below, set this parameter to the setting corresponding to the monitor item
desired for the fourth (user monitor) selection.

O1-01 User Monitor Selection

B

Setting

Description

5

Motor speed

6

Output voltage (factory default)

7

DC bus voltage

8

Output power

9

Torque reference (internal)

15

Terminal 13 input voltage level

16

Terminal 14 input voltage or current level

17

Terminal 16 input voltage level

18

Motor secondary current (Iq)

19

Motor excitation current (Id)

20

SFS output frequency

21

ASR input

22

ASR output

27

Voltage reference (Vd output)

28

CPU ID number

29

Voltage limit control output

30

qAxis current control output

31

dAxis current control output

32

Output voltage reference (Vq)

33

Output voltage reference (Vd)

41

LED check

42

Internal control status 2

43

Command 1 from option

44

Command 2 from option

45

External torque reference

46

Torque compensation value

47

DO-08H output status

48

Momentary power loss decrease capacity

49

Control section software number

50

Speed detection PG counter value

51

PID feedback

52

DI-16H input status

Section O: Operator Parameters

O1 Monitor Selection