VS-616PS5 Programming Manual

D3

Jump Frequencies

Setting Range:

0.0 to 200.0%

Factory Default:

0.0%

Setting Range:

0.0 to 200.0%

Factory Default:

1.0%

These functions allow the prohibition or “jumping” of critical Speeds so that the motor
can operate without resonant vibrations caused by some machine systems. They are
also used for dead band controls. Setting the value to 0.0% disables each function.

D3-01 Jump Speed Reference 1

A

D3-02 Jump Speed Reference 2

A

D3-03 Jump Speed Reference 3

A

D3-04 Jump Speed Reference Bandwidth

A

%

D3-02

D3-01

D3-04

D3-04

%

Set Frequency Reference

Figure 26 Jump Frequencies

D3-03

D3-04

Output

Frequency

Section D: Reference Parameters

D3 Jump Frequencies