Yaskawa VS-616PS5 Series Programming Manual User Manual
Page 38
Advertising
38
VS-616PS5 Programming Manual
D3
Jump Frequencies
Setting Range:
0.0 to 200.0%
Factory Default:
0.0%
Setting Range:
0.0 to 200.0%
Factory Default:
1.0%
These functions allow the prohibition or “jumping” of critical Speeds so that the motor
can operate without resonant vibrations caused by some machine systems. They are
also used for dead band controls. Setting the value to 0.0% disables each function.
D3-01 Jump Speed Reference 1
A
D3-02 Jump Speed Reference 2
A
D3-03 Jump Speed Reference 3
A
D3-04 Jump Speed Reference Bandwidth
A
%
D3-02
D3-01
D3-04
D3-04
%
Set Frequency Reference
Figure 26 Jump Frequencies
D3-03
D3-04
Output
Frequency
Section D: Reference Parameters
D3 Jump Frequencies
Advertising