This parameter determines how the inverter will function when switching from local to
remote operation when the external run command is applied.

1

Baseblock (factory default)- No output to motor

2

Run at minimum output speed (E1-08).

3

Zero-speed operation (internal speed reference is set to “0”)

B1-06 LOCAL/REMOTE Run Select

A

Selection

Description

0

Operation is disabled if the external run command is applied

prior to switching from local to remote. The run command

must be removed and re-applied to start operation.

1

Operation is enabled if the external run command is applied

prior to switching from local to remote.(factory default).

Setting

Description

Section B: Application Parameters

B1 Sequence