Section H: Control Circuit Terminal Parameters

H4 Analog Outputs

H4

Analog Outputs
The VS-616PS5 has two analog outputs, for the external monitoring of drive condi-
tions such as output speed, output current, PID feedback and others.

Selects the analog output monitors for terminal 21.

The resolution of terminal 21 is 9 bits plus a sign bit.

Setting Range:

±300.0%

Factory Default:

1.0

Sets the terminal 21 output gain for the analog output monitors. To obtain the output
level, multiply the monitor output level % by the gain value set in this parameter, (H4-
02).

H4-01 Terminal 21 Analog Output Selection

B

Setting

Description

1

Speed reference

2

Output Speed (factory default)

3

Inverter output current

5

Motor speed

6

Output voltage

7

DC bus voltage

8

Output power

9

Torque reference (internal)

15

External terminal 13 input voltage

16

External terminal 14 input voltage

17

External terminal 16 input voltage

18

Motor secondary current (Iq)

19

Motor excitation current (Id)

20

Primary Speed after SFS

21

Speed controller ASR input

22

Speed controller ASR output

27

qAxis current control reference

28

dAxis current control reference

29

Voltage limit control output

30

qAxis current control output

31

dAxis current control output

32

Output voltage reference (V

q

)

33

Output voltage reference (V

d

)

45

External torque reference

46

Torque compensation value

49

Control section software number

50

Speed detection PG counter value

53

PID feedback

H4-02 Terminal 21 Analog Output Gain