Yaskawa VS-616PS5 Series Programming Manual User Manual

Page 28

Advertising
background image

28

VS-616PS5 Programming Manual

C3

Voltage Limit Control

This parameter sets the voltage limit control.

C3-05 Voltage Limit Control Selection

A

Set Value

Description

0

Voltage limitation control is not performed (fac-

tory default).

1

Voltage limitation control is performed limits the

output voltage to 230 (460) by reducing the d-axis

current level.

Section C: Tuning Parameters

C3 Voltage Limit Control

Advertising