Yaskawa MotionWorks IEC Hardware User Manual

Page 131

Advertising
background image

MotionWorks IEC Hardware Configuration – 2013-03-26

128

Hex Code

Description

ErrorClass

AxisErrorID

ErrorClass+AxisErrorID output from

MC_ReadAxisError

AlarmID

AlarmID output from Y_ReadAlarm

validated. The value has been reset.

motionKernel

3201

0005

Main bus power was disconnected while the axis was
enabled. Main power must be restored and this alarm
cleared before motion can continue.

motionKernel

3201

0101

Configuration error: multiple alarm tasks with duplicate
priority.

motionKernel

3201

0102

Configuration error: Alarm task not configured. Using
default priority and name.

motionKernel

3202

0001

Axis Coordinate System: The command position was
outside the allowable range for the axis in the positive
direction (positive overtravel). The axis may not be
moved again until the alarm condition is cleared. After
the alarm is cleared, it is permissible to execute a
move which brings the axis back toward the allowed
region, even though the axis is probably still outside
the allowed region. Any move which pulls the axis
further away from the allowed region will re-trigger the
alarm.

motionKernel

3202

0002

Axis Coordinate System: The command position was
outside the allowable range for the axis in the negative
direction (negative overtravel). The axis may not be
moved again until the alarm condition is cleared. After
the alarm is cleared, it is permissible to execute a
move which brings the axis back toward the allowed
region, even though the axis is probably still outside
the allowed region. Any move which pulls the axis
further away from the allowed region will re-trigger the
alarm.

motionKernel

3202

0003

Axis Coordinate System: The command speed was
greater than the allowable range for the axis in the
positive direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0004

Axis Coordinate System: The command speed was
greater than the allowable range for the axis in the
negative direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0005

Axis Coordinate System: The command acceleration
was greater than the allowable range for the axis in the

Advertising