MotionWorks IEC Hardware Configuration – 2013-03-26

48

Selected Modbus clients and related Application Notes available
on www.yaskawa.com :

Red Lion HMI:

AN.MCD.08.122

Maple Systems HMI:

AN.MP2000iec.06

Yaskawa MP2000:

AN.MP2000.01

AB PanelView:

AN.MP2000iec.02

, E Learning Video:

eLV.MP2000iec.01.IECtoPVPlusHMI

Phoenix HMI:

AN.MP2000iec.05

Pro-face:

AN.MCD.09.124

DigiOne IAP serial to Ethernet converter:

AN.MCD.09.093

1.9.3 Adding a Modbus Server/Slave Device

The MPiec controller can communicate with up to 20 unique IP addresses
simultaneously using Modbus TCP.

A maximum of 20 data blocks of various function codes can be configured
if necessary.

The minimum poll period or update interval is 4 ms (+4 ms
tolerance.) Note that MODBUS TCP is not a deterministic protocol. Setting
a very fast update interval is not recommended because it will increase the
load on the CPU. Fast updates and high priorities should be allocated
based on application requirements)