Yaskawa MotionWorks IEC Hardware User Manual

Page 155

Advertising
background image

MotionWorks IEC Hardware Configuration – 2013-03-26

152

Hex Code

Description

ErrorClass

AxisErrorID

ErrorClass+AxisErrorID output from

MC_ReadAxisError

AlarmID

AlarmID output from Y_ReadAlarm

firmware version. If you would like to use this function
block, then the controller must be updated.

app

340C

F110

All error codes for kernel errors range from 0xF111 to
0xF11f.

app

340C

F111

An internal assertion in the motion kernel failed
indicating the controller is not in a stable state. This
error should be reported to Yaskawa Electric America.

user

3501

0000

A user script task posted an alarm directly.

motionKernel

4202

0001

The command position will soon reach the allowable
range for the axis in the positive direction (positive
overtravel). The axis may not be moved again until the
alarm condition is cleared. After the alarm is cleared, it
is permissible to execute a move which brings the axis
back toward the allowed region, even though the axis
is probably still outside the allowed region. Any move
which pulls the axis further away from the allowed
region will re-trigger the alarm.

motionKernel

4202

0002

The command position will soon reach the allowable
range for the axis in the negative direction (negative
overtravel). The axis may not be moved again until the
alarm condition is cleared. After the alarm is cleared, it
is permissible to execute a move which brings the axis
back toward the allowed region, even though the axis
is probably still outside the allowed region. Any move
which pulls the axis further away from the allowed
region will re-trigger the alarm.

motionKernel

4202

0003

The command speed will soon reach the allowable
range for the axis in the positive direction (overspeed).
The axis may not be moved again until the alarm
condition is cleared.

motionKernel

4202

0004

The command speed will soon reach the allowable
range for the axis in the negative direction
(overspeed). The axis may not be moved again until
the alarm condition is cleared.

motionKernel

4202

0005

The command acceleration will soon reach the
allowable range for the axis in the positive direction.
The axis may not be moved again until the alarm
condition is cleared.

Advertising