MotionWorks IEC Hardware Configuration – 2013-03-26

130

Hex Code

Description

ErrorClass

AxisErrorID

ErrorClass+AxisErrorID output from

MC_ReadAxisError

AlarmID

AlarmID output from Y_ReadAlarm

greater than the allowable range for the axis in the
negative direction (overspeed). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0015

Joint Coordinate System: The command acceleration
was greater than the allowable range for the axis in the
positive direction. The axis may not be moved again
until the alarm condition is cleared.

motionKernel

3202

0016

Joint Coordinate System: The command acceleration
was greater than the allowable range for the axis in the
negative direction. The axis may not be moved again
until the alarm condition is cleared.

motionKernel

3202

0017

Joint Coordinate System: The command torque was
greater than the allowable range for the axis in the
positive direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0018

Joint Coordinate System: The command torque was
greater than the allowable range for the axis in the
negative direction (overtorque). The axis may not be
moved again until the alarm condition is cleared.

motionKernel

3202

0021

World Coordinate System: The command position was
outside the allowable range for the axis in the positive
direction (positive overtravel). The axis may not be
moved again until the alarm condition is cleared. After
the alarm is cleared, it is permissible to execute a
move which brings the axis back toward the allowed
region, even though the axis is probably still outside
the allowed region. Any move which pulls the axis
further away from the allowed region will re-trigger the
alarm.

motionKernel

3202

0022

World Coordinate System: The command position was
outside the allowable range for the axis in the negative
direction (negative overtravel). The axis may not be
moved again until the alarm condition is cleared. After
the alarm is cleared, it is permissible to execute a
move which brings the axis back toward the allowed
region, even though the axis is probably still outside
the allowed region. Any move which pulls the axis
further away from the allowed region will re-trigger the
alarm.