MotionWorks IEC Hardware Configuration – 2013-03-26

81

Three pulse counting methods are supported:

Sign (One channel counts, the other indicates the direction.)

Up/Down (One channel indicates forward, the other channel
indicates reverse.)

A/B (Quadrature)

This section describes the details on each pulse counting method: