Message Send and Receive Functions

6.2 Message Receive Function

6.2.3 Inputs and Outputs for the Message Receive Function

6-19

[ d ] Pro-Typ (Communication Protocol)

The Pro-Typ input specifies the communication protocol as shown in the following table.

The following table summarizes the correspondence between the FL-net message and Pro-Typ.

∗ 1. Because a response is sent from within the 262IF-01, neither receive processing by applications (MSG-RCV func-

tion) nor send processing by applications (MSG-SND function) is required.

∗ 2. A response is received by application send processing (MSG-SND function). The MSG-RCV function is not

required.

Œ

For the relationship between the FL-net message and message function, refer to 6.3 Combination of FL-net Mes-
sages and Message Functions
on page 6-29.

[ e ] Cir-No (Circuit Number)

The Cir-No input specifies the circuit number of the transmission device.
Set the circuit number to the value displayed in the MPE720 Module Configuration Window.

The valid circuit number range of FL-net is 1 to 8.

Type code

Communication Protocol

Remarks

1

MEMOBUS

Select for word block read or word block write of FL-net messages.

2

Non-procedure protocol 1
(in units of words)

Select for other than the above message.
Data will be received in word units using the non-procedure protocol. No
response is sent to the remote station.

3

Non-procedure protocol 2
(in units of bits)

Not used in FL-net.

Message Type

Function

Communication Protocol

Server

(Send

Response)

Client

(Send Request)

Word block read

Reads data in units of words.

MEMOBUS

*2

Word block write

Writes data in units of words.

MEMOBUS

*2

Network parameter read

Reads network parameter data.

*1

Non-procedure 1

Network parameter write

Writes network parameter data.

Not supported

Non-procedure 1

Stop command

Stops operation of equipment such as the PC connected
to the upper layer of the FA link protocol.

Not supported

Non-procedure 1

Start command

Starts operation of equipment such as the PC connected
to the upper layer of the FA link protocol.

Not supported

Non-procedure 1

Profile read

Reads a device profile.

*1

Non-procedure 1

Transparent message

Provides a transparent service to the upper layer of the
FA link protocol.

Non-procedure 1

Non-procedure 1

Log data read

Reads log data concerning a specified node.

*1

Non-procedure 1

Log data clear

Clears log data concerning a specified node.

*1

Non-procedure 1

Message loopback

Loops back a received message.

*1

Non-procedure 1

Circuit number