( 2 ) MP2200 Machine Controller

∗ Racks 2 to 4 can be used only when using EXIOIF.

( 3 ) MP2300 Machine Controller

Name

Register No.

Remarks

I/O Error Count

SW00200

Number of I/O error occurrences

Number of Input Errors

SW00201

Number of input error occurrences

Input Error Address

SW00202

Address of the latest input error (IW………… register num-
ber)

Number of Output Errors

SW00203

Number of output error occurrences

Output Error Address

SW00204

Address of the latest output error (OW………… register
number)

Reserved by the system

SW00205

Not used.

SW00206
SW00207

I/O Error Status

SW00208 to SW00215

Not used.

SW00216 to SW00223

Reserved by the system

SW00224 to SW00228

Error status of slot 1 of rack 1
(Depends on the mounted module and error code.)

SW00229 to SW00239

Error status of slot 2 of rack 1
(Depends on the mounted module and error code.)

SW00240 to SW00247

Error status of slot 3 of rack 1
(Depends on the mounted module and error code.)

SW00248 to SW00255

Error status of slot 4 of rack 1
(Depends on the mounted module and error code.)

...

...

SW00496 to SW00503

Error status of slot 9 of rack 4

*

(Depends on the mounted module and error code.)

Name

Register No.

Remarks

I/O Error Count

SW00200

Number of I/O error occurrences

Number of Input Errors

SW00201

Number of input error occurrences

Input Error Address

SW00202

Address of the latest input error (IW………… register num-
ber)

Number of Output Errors

SW00203

Number of output error occurrences

Output Error Address

SW00204

Address of the latest output error (OW………… register
number)

Reserved by the system

SW00205

Not used.

SW00206
SW00207

I/O Error Status

SW00208 to SW00215

Slot 0 error status
(Depends on the mounted module and error code)

SW00216 to SW00223

Reserved for the system

SW00224 to SW00231

Slot 1 error status
(Depends on the mounted module and error code.)

SW00232 to SW00239

Slot 2 error status
(Depends on the mounted module and error code.)

SW00240 to SW00247

Slot 3 error status
(Depends on the mounted module and error code.)