Yaskawa JAPMC-MC2303-E User Manual

Page 35

Advertising
background image

3

Mounting and Starting the Module

3.2 Mounting and Removing a Module on Machine Controller

3.2.1 Mounting a 262IF-01 Module

3-5

( 4 ) Procedure after Mounting the Module

1.

Connect the Hub.

Connect the hub to the 262IF-01 Module using the Ethernet cable.

Œ

Refer to 2.2.2 Cable Specifications on page 2-8 for cables that can be used.

2.

Create Module Configurations.

a) Mounting New Modules

Execute self-configuration for each slot in which a 262IF-01 Module was mounted.

Œ

Refer to 3.4 Self-configuration on page 3-19 for information on self-configuration.

b) Replacing Modules

Turn OFF the CNFG and INIT DIP switch pins on the Machine Controller and turn ON the power supply.
Once the power has been turned ON, the module configuration can be modified as required.

Œ

Refer to 4.1.1 Displaying the Module Configuration Window on page 4-2 for information on the Module config-

uration.

Œ

A Communication Module other than the 262IF-01 Module is required for communication between the
Machine Controller and the personal computer running the MPE720. Be sure to mount the Communication
Module and refer to 3.3 Setting the Communication Manager on page 3-8, 3.4 Self-configuration on page 3-
19, and 3.5 Starting the MPE720 and Setting Communication or Network Parameters on page 3-20 to make
the required settings before creating module configurations.

Advertising