B.6 fl-net status management, B.7 fl-net message serial number management, A-13 – Yaskawa JAPMC-MC2303-E User Manual

Page 163: 1 ) basic function, 2 ) management data

Advertising
background image

Appendix B FL-net Network Management

B.6 FL-net Status Management

A-13

App

Appendices

B.6

FL-net Status Management

( 1 ) Basic Function

Manages network status parameters.

( 2 ) Management Data

B.7

FL-net Message Serial Number Management

( 1 ) Basic Function

Manages serial numbers and their version numbers in message transmission.

( 2 ) Management Data for Sending

( 3 ) Management Data for Receiving

Item

Byte Length

Contents

Token holding node number

1 byte

Node holding token at present
(1 to 254)

Minimum allowable frame interval

1 byte

Unit: 100

μs (0 to 50)

Refresh cycle allowable time

2 bytes

Unit: 1 ms (1 to 65535)

Refresh cycle measurement time
(Current value)

2 bytes

Unit: 1 ms (1 to 65535)

Refresh cycle measurement time
(Maximum value)

2 bytes

Unit: 1 ms (1 to 65535)

Refresh cycle measurement time
(Minimum value)

2 bytes

Unit: 1 ms (1 to 65535)

Item

Byte Length

Contents

Serial version number

4 bytes

Serial numbers for send messages

Serial number (1:1 sending)

4 bytes

1 to FFFFFFFFH

Serial number (1:n sending)

4 bytes

1 to FFFFFFFFH

Item

Byte Length

Contents

Serial version number

4 bytes

1 to FFFFFFFFH

Serial number (1:1 receiving)

4 bytes

1 to FFFFFFFFH

Serial number (1:n receiving)

4 bytes

1 to FFFFFFFFH

Advertising