3 system i/o error status – Yaskawa JAPMC-MC2303-E User Manual

Page 143

Advertising
background image

7

T

roubleshooting

7.2 Common Network Problems and Countermeasures

7.2.3 System I/O Error Status

7-5

7.2.3 System I/O Error Status

The following shows the system I/O error status of the MP2000 Series Machine Controller.
Refer to 6.4.1 Displaying a Register List on page 6-30 and specify a system register number “SW†††††” to
access.

( 1 ) MP2100M Machine Controller

∗ Racks 2 to 4 can be used only when using MP2100MEX.

Lit

Lit

Lit

8000 (local node)
8000 (other node)

0061 (local node)
0061 (other node)

0080

The common mem-
ory settings do not
match those of the
other node.

Collect network configuration
information on the Network
Configuration
window for
FL-net transmission defini-
tion, check the common mem-
ory settings of the other nodes
and then change the link
assignment.

Lit

Lit

Lit

8000 (local node)
0000 (other node)

0061 (local node)
0061 (other node)

0080

The upper layer of a
remote node has
been stopped.

Activate the upper layer of the
remote node.

(cont’d)

LED

Link Status

Status

Causes

Countermeasures

RUN

ERR

LNK

Upper Layer

FA Link

Name

Register No.

Remarks

I/O Error Count

SW00200

Number of I/O error occurrences

Number of Input Errors

SW00201

Number of input error occurrences

Input Error Address

SW00202

Address of the latest input error (IW………… register num-
ber)

Number of Output Errors

SW00203

Number of output error occurrences

Output Error Address

SW00204

Address of the latest output error (OW………… register
number)

Reserved by the system

SW00205

Not used.

SW00206
SW00207

I/O Error Status

SW00208 to SW00215

MP2100M Machine Controller error status

SW00216 to SW00223

Reserved by the system

SW00224 to SW00228

SVB-01 Module error status

SW00229 to SW00239

Reserved by the system

SW00240 to SW00247

Error status of slot 1 of rack 2

*

(Depends on the mounted module and error code.)

SW00248 to SW00255

Error status of slot 2 of rack 2

*

(Depends on the mounted module and error code.)

SW00256 to SW00263

Error status of slot 3 of rack 2

*

(Depends on the mounted module and error code.)

SW00264 to SW00271

Error status of slot 4 of rack 2

*

(Depends on the mounted module and error code.)

...

...

SW00448 to SW00455

Error status of slot 9 of rack 4

*

(Depends on the mounted module and error code.)

Advertising