4.2 FL-net Transmission Definition

4.2.1 Transmission Parameters Tab Page

4-4

4.2 FL-net Transmission Definition

4.2.1 Transmission Parameters Tab Page

Set the parameters required for FL-net communication. The following gives a detailed description.

„

Configuration Information

The 262IF-01 configuration information is displayed. This configuration information is the same as the information
displayed in the Module Details Area in the Module Configuration Window.

RACK#: The rack number of the rack in which the 262IF-01 is defined.
Slot#: The slot number of the slot in which the 262IF-01 is defined.
CIR#: The circuit number of the Ethernet port on the 262IF-01.

Œ

When the MSG-SND or MSG-RCV function is used, set the circuit number displayed here for CIR# (circuit
number).

„

Setting the Transmission Parameters

IP Address

Set the IP address of the local node. The last digit is used as a module node number.
There are four 8-bit fields delimited by periods (.). Input a decimal number for each field.

Œ

Do not use the same address as another node. If a duplicate IP address is entered, undetect will be selected
as Bit 7 Address overlapping detection in the Status Detail Window (refer to page 4-10), resulting in a dis-
abled network connection.

Subnet Mask

Set the subnet mask for the IP address of the local node.
Since “255.255.255.0” is automatically set in FL-net, use this default value.

Token monitoring time

Set the monitoring time in units of ms from when the node acquires the token until the node issues a token.
This time can be set in a range from 1 to 255 (ms).

Minimum permissible frame interval

Set the time in units of 100

μs from when the local node receives a token from a remote node until the local node

sends a frame.
This time can be set in a range from 0 to 50 (0-5 ms).

1

2

3

4
5

6

Configuration
information

1

Field No. 4: Module node numbers 1 to 254

Field No. 2: 0 to 255
Field No. 1: 192 to 223

Field No. 3: 0 to 255

2

3

4