Troubleshooting – Rose Electronics Orion X-series User Manual

Page 109

Advertising
background image

TROUBLESHOOTING

Orion X Installation and Operations Manual

101

Troubleshooting

This section deals with troubleshooting possible problems on the Orion X matrix. The solutions outlined
here are contingent on having a functional extender route. Please ensure before running the extenders
with the matrix that they work in a peer-to-peer connection. This can be accomplished by the use of a Cat
X or fiber coupler. This information can be found in the manuals of the respective extenders.

External Failure

Problem

Possible Reason

Solution

Matrix will not power up

Fuse at the standard appliance
outlet

 Check fuse.

Video Interference

Problem

Possible Reason

Solution

Unable to open OSD

OSD Jumper not set

 Set jumper 11 on the CON unit.

Incorrect video display

Cable connection faulty

 Check the connections, length
and quality of the interconnect cable
to the units.

Fan Malfunction

Problem

Possible Reason

Solution

Fans only run under full load

Communication to fan tray is
faulty

 Remove and reinstall the fan tray
 Swap the fan trays to the other
slot.
 Restart the matrix.

Fans do not run, LED OK on

Fans defective

 Contact your dealer

Fans do not run, LED OK off

Power supply

 Check power supply and power
connection

Power Supply Unit Malfunction

Problem

Possible Reason

Solution

Matrix cannot be started

Power Supply Units not locked
correctly

 Check lock and plug-in of the
Power Supply Units

No power supply available

 Check that the power supply
cables are connected properly

Power Supply Units are not
switched on

 Check slide to switch on the
Power Supply Units

Network Error

Problem

Possible Reason

Solution

Network settings are not used
after editing

Restart of the matrix not yet
completed

 Restart the matrix

Advertising