Rose Electronics Orion X-series User Manual

Page 90

Advertising
background image

82

Orion X Installation and Operations Manual

To disconnect an existing connection between CON and CPU devices proceed as follows:

1. Click on the port that has to be disconnected by using the right mouse button.

2. Select the

Disconnect function in the popup that appears. The connected ports will be

disconnected immediately. At the same time any other connections of extenders assigned to the

involved devices will be disconnected.

USB 2.0 Switching

Switching of USB 2.0 extenders basically works like switching of KVM extenders. There are two

possibilities for switching USB 2.0 extenders, depending on how the extenders are set up in the Matrix.

1. USB 2.0 extenders that were created and assigned to an existing device with KVM extender units.

2. USB 2.0 extenders that were created as a separate device which contains no KVM extender units.

This allows switching of USB 2.0 equipment independent of KVM devices.

Notes:

The separate switching of USB 2.0 signals requires the methods described in the section on

Extended Switching above.

When switching USB 2.0 equipment, wait until the CPU enumeration of USB 2.0 devices has been

completed before switching to the next CPU (approximately. 5-15 seconds). Failure to allow

enough time for USB 2.0 device enumeration can negatively affect the stability of the connection.