Orion X Installation and Operations Manual

Switch to previous CPU

1. Start Command Mode with the 'Hot Key'.

The keyboard LEDs

Caps Lock and Scroll Lock will flash when Command Mode is active.

2. Press the <p> key on the keyboard.

Command Mode is closed and the console is connected to the previous CPU with complete

control.

Notes:

If the matrix is switched to a CPU that was previously connected with Video Only Access, it will

now be connected to this CPU with full KVM access.

The matrix only allows switching to unused and allowed CPUs with the 'Hot Keys'. The

Force

Connect and Force Disconnect options, as well as the restrictions of the User ACL and CON

ACL are taken into account. ‘Hot Keys' are only supported, if neither

Enable User Login nor the

Enable User ACL are selected and the user is logged in the OSD.

Scan Mode

The Scan Mode shows video signals of the different CPU favorites quickly and without delay, and switches

between them without continuously using the 'Hot Key'. The switching between two video signals can even

take place within one frame.

1. Start command mode with the 'Hot Key'. The keyboard LEDs

Caps Lock and Scroll Lock will flash

when Command Mode is active.

2. Press the <Left Shift> key and hold it down. The index numbers of the various CPUs from the list of

favorites can be entered on the keyboard, causing the matrix to immediately switch to the video

signal of the respective CPU after entering the index number.

3. Leave Scan Mode by pressing <Left Shift> + <Esc>.

Note: Optimal scan mode results can be achieved by the use of CPU resolutions as close to identical as

possible. This contributes to a smooth and seamless function of the scan mode.

Function Keys <F1>-<F16>

In Command Mode, macros 1-16 can be retrieved with the function keys <F1>–<F16> of the connected

standard keyboard instead of the special macro keyboard.

Command Mode is closed and the stored command sequence for the appropriate function key is executed.

For macros, there is no need to use the <Enter> key for confirmation.