104

Orion X Installation and Operations Manual

Fiber SFP Type LC (Interconnect)

The communication of fiber devices is performed via Gigabit SFPs that have to be connected to suitable

fibers fitted with type LC connectors.

Note:

The correct function of the device can only be guaranteed with SFPs provided by the manufacturer.

SFP modules can be damaged by electrostatic discharge (ESD). Please consider ESD handling

specifications.

SDI (Interconnect)

The communication of the SDI devices requires a mini coax connection with mini BNC connectors or 3G

SFPs with transmission speeds of 0,360 Gbit/s (SD-SDI, SMPTE 259M), 1,485 Gbit/s (HD-SDI, SMPTE

292M) and 2,970 Gbit/s (3G SDI).

Interconnect Cable

The cables used to connect the Orion X to the extenders are described here.

CATx

A point-to-point connection is required. Operation with several patch fields is possible. Routing over an

active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.

Avoid routing Cat X cables near power cables.

If the site has 3-phase AC power, try to ensure that CPU Unit and CON Unit are on the same phase.

Notes:

To maintain regulatory EMC compliance, correctly installed shielded Cat X cable must be used

throughout the interconnection link.

To maintain regulatory EMC compliance, all Cat X cables should have ferrites installed on both cable

ends close to the devices.

Type of Interconnect Cable

The Orion X requires interconnect cabling specified for Gigabit Ethernet (1000BASE-T). The use of solid-

core (AWG24), shielded, Cat 5e (or better) is recommended.

Cat X Solid-Core Cable

AWG24

S/UTP (Cat 5e) cable according to EIA/TIA-568-B. Four pairs of wires

AWG24. Connection according to EIA/TIA-568-B (1000BASE-T).

Cat X Patch Cable

AWG26/8

S/UTP (Cat 5e) cable according to EIA/TIA- 568-B. Four pairs of wires

AWG26/8. Connection according to EIA/TIA-568-B (1000BASE-T).

The use of flexible cables (patch cables) type AWG26/8 is possible, however the maximum possible

extension distance is halved.

Maximum Acceptable Cable Length

Cat X Installation Cable

AWG24

400 ft (140 m)

Cat X Patch Cable

AWG26/8

200 ft (70 m)