Orion X Installation and Operations Manual

105

Fiber

A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over

active network components, such as Ethernet Hubs, Matrixes or Routers, is not allowed.

Type of Interconnect Cable

(Cable notations according to VDE)

Type of cable

Specifications

Single-mode 9μm

Two fibers 9μm

I-V(ZN)H 2E9 (in-house patch cable)

I-V(ZN)HH 2E9 (in-house breakout cable)

I/AD(ZN)H 4E9 (in-house or outdoor breakout cable, resistant)

A/DQ(ZN)B2Y 4G9 (outdoor cable, with protection against rodents)

Multi-mode 50μm

Two fibers 50μm

I-V(ZN)H 2G50 (in-house patch cable)

I/AD(ZN)H 4G50 (in-house or outdoor breakout cable, resistant)

Multi-mode 62.5μm

Two fibers 62.5μm

I-V(ZN)HH 2G62,5 (in-house breakout cable)

A/DQ(ZN)B2Y 4G62,5 (outdoor cable, with protection against rodents)

Note: Only use Single-mode connection cables for fiber connections that are based on 3G SFPs.

Maximum Acceptable Cable Length

Type of cable

1.25 Gbps

3.125 Gbps

Single-mode 9μm

32,800 ft (10,000 m) 16,400 ft (5,000 m )

Multi-mode 50μm (OM3) 3,280 ft (1,000 m)

1,640 ft (500 m)

Multi-mode 50μm

1,300 ft (400 m)

650 ft (200 m)

Multi-mode 62.5μm

650 ft (200 m)

325 ft (100 m)

If single-mode SFPs are used with multi-mode fibers, you normally can increase the maximum acceptable

cable length.

Type of Connector

Type of connector LC Connector

Coaxial

A point-to-point connection is necessary.

Type of Interconnect Cable

Cable Type

Specifications

Mini coaxial cable AWG 18 RG 6

impedance 75 Ω

Maximum Acceptable Cable Length

Band width Maximum acceptable cable length

0.270 Gbit/s 1,312 ft (400 m)

1.485 Gbit/s 459 ft (140 m)

2.970 Gbit/s 394 ft (120 m)

Type of Connector

Type of connector Mini BNC Connector

Advertising