Rose Electronics Orion X-series User Manual

Page 41

Advertising
background image

Orion X Installation and Operations Manual

33

Switch Settings

The configuration of the switching parameters is set in this menu. This menu can be accessed in the OSD

and the Java Tool.

The following settings can be modified.

Field

Selection

Description

Video Sharing

Activated

The user can switch to any CPU as an observer, even to such ones

that are already assigned to another user (observer without

keyboard/mouse access).

Note: Switching is done with the <Space> key, not <Enter>.

The operator will not be informed if further users connect as an

observer to the CPU that is connected to his console.

Deactivated

Function not active (default)

Force Connect

Activated

The user can connect to every single CPU as an operator, even to

such ones that are related to another user.

Note: The previous user is set to video only status.

To share K/M control,

Force Connect has to be activated.

Deactivated

Function not active (default)

Force

Disconnect

Activated

Extension of

Force Connect: If the user connects to a CPU as an

operator that is already related to another user, the connection to the

previous user will be completely disconnected.

Note: To share K/M control Force Disconnect has to be

deactivated.

Deactivated

Function not active (default)

CPU Auto

Connect

Activated

If a console is not connected to a CPU, an automatic connection to

the next available CPU can be established by hitting any key or

mouse button.

Deactivated

Function not active (default)

CPU Timeout

0-999

minutes

Period of inactivity after which a console will be automatically

disconnected from its current CPU (default value: 0 minutes)

Keyboard

Connect

Activated

Activate request of K/M control by keyboard event (key will be lost)

Deactivated

Function not active (default)

Mouse Connect

Activated

Activate request of K/M control by mouse event

Deactivated

Function not active (default)

Release Time

0-999

seconds

Period of inactivity of a connected console after which K/M control

can be requested by other consoles connected to the CPU.

Note: Set "0" for an immediate transfer in real-time.

Only one console can have keyboard and mouse control at the

same time. The other consoles that are connected to the same

CPU have a video only status (default value: 10 seconds)

If the

Keyboard Connect and/or Mouse Connect options are activated, the Release Time condition will

have to be met before a new user can gain control.